Every year many people are injured and some killed due to contact with buried services.
Gas
- Check the gas company plans before digging.
- Dig carefully by hand to establish the location of pipes and mark the route of all known pipes.
- Remember gas is flammable and explosive.
- At the slightest hint of gas escape, leave the area and do not smoke. Call the gas company and emergency services.
- Modern, smaller diameter house mains are often plastic. Don’t confuse them with electric cables.
- Follow the gas company specification for back filling.
Water Mains
- Trace the line of the main by trial pits and mark the route of all known pipes.
- Burst pipes can fill excavations quickly. If damaged, call the water company.
- Remember: Water at high pressure could be dangerous.
- Never leave a length of pipe unsupported.
Sewers
- There is a severe health risk if a foul sewer is fractured – leave the excavation and report it.
- Wear personal protective equipment (PPE) due to risk of contamination from sewerage.
- Wash your hands before eating and smoking.
- If you break a stormwater sewer and rain is falling, vacate the excavation as flooding may occur.
- Ladder access should be provided into deep excavation.
Colour-coding system for buried services
- Red – Electricity
- Blue – Water
- Yellow – Gas
- Grey – Telecommunications
- Green – Cable Television
Remember all buried services have the potential to cause injury or illness
Electricity on site is a separate Toolbox Talk